GB/T 2423.10 1995 electrical and electronic products environmental test in the second part: test method for testing the Fc and guideline: vibration (sinusoidal);
GB/T 2423.11 1997 electrical and electronic products environmental testing part 2: test method test Fd: wide band random vibration - general requirements;
GB/T 2423.12 1997 electrical and electronic products environmental testing part 2: test method for testing the Fda: wide band random vibration, high reproducibility;
GB/T 2423.13 1997 electrical and electronic products environmental testing part 2: test method test Fdb: wide band random vibration of reproducibility;
GB/T 2423.14 1997 electrical and Carbon in Pulp electronic products environmental testing part 2: test method test Fdc: wide band random vibration low reproducibility;
GB/T 2423.35 1986 basic electrical and electronic products environmental test procedure test Z/AFc: cooling and cooling test samples/vibration (sinusoidal) integrated test method at low temperature;
GB/T 2423.36 1986 basic electrical and electronic products environmental test procedure test Z/landing: the heat/vibration of cooling and heat dissipation sample (sinusoidal) integrated test method;
GB/T 2423.48 1997 electrical and electronic products environmental testing part 2: test method test Ff: vibration, the time history method;
GB/T 2423.49-1997 - part 2: electrical and electronic products environmental test experiment method of Fe: - sine vibration frequency method;
GB/T 2424.22 86 electrical and electronic products are the basic environmental testing procedures temperature (low temperature, high temperature) and the vibration is (xuan) comprehensive test guideline;
GB/T 2424.24 1995 electrical and electronic products are the basic environmental testing procedures (low temperature, high temperature/pressure/temperature vibration (is the xuan) integrated test guideline.
Installation of the specimens
1, open air chrome washing machine pump, manual regulation center air pressure to the center;
2, clamp, installed in strict accordance with the test specification requirements for installation of the specimens;
3. Sensor installed in strict accordance with the test specification requirements is a message to paste, and for the specified purposes;
4, with the corresponding signal lines connect the sensor to test specification specified control instrument channel;
Boot sequence
1, turn on the system power supply, to determine the gain switch is in the reset position, close the power amplifier leakage circuit breakers;
2, according to the requirements of test tasks to receive correct set parameters, and save, you have to check if the call test data test Settings are consistent with the test specification; 3, press the power button, the fan starts. Open the gain knob to the right position (see instructions)/at this point "to" start "" power" lights, into a state system to run.
4, run test, real-time measuring and test gold CIP machine equipment state, save the corresponding experimental data.